RF-power and temperature data analysis of 444 patients with primary cervical cancer: Deep hyperthermia using the Sigma-60 applicator is reproducible

Fatehi, D. and Van Der Zee, J. and de Bruijne, M. and Franckena, M. and Van Rhoon, G.C. (2007) RF-power and temperature data analysis of 444 patients with primary cervical cancer: Deep hyperthermia using the Sigma-60 applicator is reproducible. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 23 (8). pp. 623-643.

Full text not available from this repository.

Abstract

Treatment reproducibility is important to guarantee reproducible treatment-outcome, a low-complication rate and efficient treatment procedures. This study evaluated the performance of loco-regional deep hyperthermia with four BSD-2000 configurations during 1990-2005 using the direct available parameters, i.e., temperature and power. Primary cervical cancer patients (n = 444) were all treated within the Sigma-60. Patients were grouped in three weight-groups: < 61 kg, 61-70 kg, > 70 kg. Different temperature and power indices were extensively analyzed per BSD configuration, per weight-group, and over the time-period. No substantial variations were found for temperature/power indices over the four BSD configurations or for the temperature doses in similar weight-groups. The `bare' power indices were increased with weight; however, the derivative power-related (W/kg, W/cm(2)) and temperature indices decreased. Large variations were found in the power-related parameters during 1991-1996 (1st time-period), whereas they were much smaller during 1997-2005 (2nd time-period). The most relevant change noted was the adaptation of the treatment strategy with respect to power modulation. The average frequency of switched-off was 3.4 and 8.9 times/treatment session for the 1st and 2nd time-period, respectively, while the average duration of each switched-off time was 78.2 vs. 38.3 s. The yearly average of vagina T-50 was in the range of 39.3-40.2 degrees C (1st time-period) and 40.0-40.5 degrees C (2nd time-period). In 40% of the patients, a positive correlation was found between normalized net integrated power per pelvic area and vagina T50. Good reproducible heating is achieved with the BSD-2000 Sigma-60 irrespective of the regular technological upgrades of the system and variation of trained staff-members.

Item Type: Article
Uncontrolled Keywords: hyperthermia; cervical cancer; temperature; RF-power; BSD-2000; Sigma-60; thermal dosimetry; reproducibility
Subjects: WP Gynecology
QZ pathology-Neoplasms
Divisions: Faculty of Medicine > Department of Clinical Sciences > Department of Radiology
Depositing User: zahra bagheri .
Date Deposited: 19 Aug 2017 07:53
Last Modified: 19 Aug 2017 07:53
URI: http://eprints.skums.ac.ir/id/eprint/3159

Actions (login required)

View Item View Item